ŒfÚŽGŽi˜ajF
“y–ØŠw‰ï˜_•¶W I
ŠªF
-Šª
†F
386/I-8†
•ÅF
387]396•Å
”NF
1987”N
ŒŽF
10ŒŽ
’˜ŽÒi˜ajF
¯’JŸ, ‘å–ìt—Y
ƒ^ƒCƒgƒ‹i˜ajF
kÐŽž×²Ìײ݂̑ŠŒÝ‰e‹¿‚ðl—¶‚µ‚½•œ‹Œ‰ß’ö‚Ì‹@”\•]‰¿–@
|
´˜^i˜ajF
-
ƒL[ƒ[ƒhi˜ajF
-
|
ŒfÚŽGŽi‰pjF
JOURNAL OF STRUCTURAL MECHANICS AND EARTHQUAKE ENGINEERING
’˜ŽÒi‰pjF
ƒ^ƒCƒgƒ‹i‰pjF
Inter]chain effect of lifelines on their aseismic performanceD
|
´˜^i‰pjF
In order to investigate disaster restoration and system performance recovery of lifelines, a model is required which can forecast quantitatively time sequential changes in the restoration process. For this purpose, a functional evaluation model which treats the mechanism of disaster's influence, was described, and then a quantitative and realistic functional evaluation model which takes into consideration inter-chain between lifelines was derived. Utilizing a method of system dynamics (S.D.), the whole functional evaluation of electric power and water supply systems which play the most important role in lifeline systems was investigated.
|
|
ƒL[ƒ[ƒhi‰pjF
-
|
‹LŽ–‹æ•ªF
-
‹æ•ª
@@@@˜_•¶W